Solar System Sizing for Hotels, Offices, and Factories: Sizing Guide
To size commercial solar for hotels, offices, and factories: 1) Determine average monthly consumption (units), 2) Calculate average daytime consumption percentage (typically 65%–80% for offices and factories), 3) Size solar capacity so annual generation matches daytime demand without excessive uncredited export, and 4) Verify that your roof area provides at least 80–100 sq.ft per kW.
Step 1: Analyzing Contract Demand and Sanctioned Load
In Maharashtra, MSEDCL net-metering regulations cap solar capacity at your approved Sanctioned Load or Contract Demand. Sizing must comply with these statutory boundaries.
Step 2: Matching Generation with Operational Load Profiles
For commercial offices operating 9 AM to 6 PM, 100% of solar generation is consumed on-site. For 24x7 facilities like hotels or hospitals, solar handles the heavy daytime AC chilling and kitchen loads, leaving night baseload to the grid.
Step 3: Rooftop Shadow Analysis & Obstacle Layout
Commercial roofs frequently contain HVAC chillers, cooling towers, ventilation ducts, and water tanks. A 3D CAD shadow simulation ensures panels are placed exclusively in unshaded zones.